ELF Audits
Powerline EMF Audits
Minimum Order Quantity: 1000 sq ft
Product Brochure
Service Charges | Rs.5 per sq feet |
Coverage Area | >1000 Square Feet |
Technology | EMF (ELF) surveys,Magnetic shielding. |
Service Includes | ELF and EMF radiation audit |
Process | Dual Vector field study |
Device Calibration | Available. Provided with report |
Risk levels covered | Device immunity,Generic human exposure,surge voltages,Occupational exposures,ESD risks. |
Solutions | ELF plotting,EMF plotting,Source shielding,area dimensioning and planning |
Categories | Power line ELF,domestic device ELF,ELF/EMF from other sources at home.. |
ELF audits are done closer to electrical transmission and distribution panels and other heavy electrical equipment. This includes transformers, HT power transmission lines, electrical engines, invertors, batteries etc. This is essentially done in 0-100Hz range.
EMF audits are done on a longer frequency band (around 100KHz or 100MHz).
We provide audits done by the NARDA EHP50F - which is the only calibrated and portable device in India for ELF/EMF audits.
Additional Information:
- Delivery Time: 2 days from advance payments or purchase order.
Premise ELF Radiation Audits
Product Brochure
Measurement range, E field | 5 mV/m to 100 kV/m |
Temperature range | -20 DegreeC to +55 DegreeC |
Dynamic range | > 105 dB |
Product description 1 | Isotropic measurement of electric and magnetic ELF fields |
Product description 2 | Frequency selective FFT measuring system with high dynamic range for electric and magnetic fields fr |
Device used | NARDA EHP50F / Trifield 100XE |
Frequency range | 1Hz to 400 KHz |
Heat Mapping Software | L3Harris |
Measurement range, H field | 0.3 nT to 10 mT |
We provide safety audits for ELF (extreme low frequency) radiation. ELF radiation is emitted by heavy electrical machinery (transformers, substations, switchgear) or high power distribution systems (440KV, 220KV, 110KV).
ELF radiation is measured in terms of Residual AC Electric fields and AC Magnetic fields
What ELF audits cover?
- Measurements of Residual/ Ambient Electric & magnetic field vectors from current carrying conductors
- Power line immunity and susceptibility for Class A, B, C, D, E types of devices (vide. EN 61000-4-8)
- Risk simulation due to sag, humidity, load and other factors
- Fitness of premise in terms of exposure to Electric & Magnetic fields Premise risk dimensioning
- Electro static discharge risks from overhanging high power transmission lines (vide. EN 61000 -6-2)
- Data centre active monitoring for high electric and magnetic fields
- Premise 2D vector mathematical modelling of High power transmission lines
- ELF Field fitness for production premise
- ELF area fitness studies
- Studies corresponding to human exposures (General population, Occupational)
- IT equipment ELF susceptibility studies
- Data centre ELF interference studies
- Power line immunity studies
Additional Information:
- Production Capacity: 100 -120 points as per sampling strategy per day
- Delivery Time: +5-7 days post confirmation
- Packaging Details: Audit delivery includes 1. Audit summary 2. Full document Audit report 3. Machine data